Devimat™ DSVF150 - Installation Picture Gallery

 

The following pictures will help to illustrate the finished results of an Undertile installation. You may need to increase the page size to clearly see some details - hold the Crtl key and tap the "+" key to increase and the "-" key to decrease.

Kitchen 01Kitchen (view beside Breakfast bar)
LEFT: The "Cold Tail" joint is showing at the top of the picture. From this point, you can follow the "path" the installer has used to ensure that the two "Cold Tails" arrive back at the same point. RIGHT Shows the "hidden" section to the right of the Cold Tail position.
  
  
Kitchen with Cold Tail view 01Kitchen showing Cold Tail Supply from behind a Fridge
These two pictures show the "Cold Tail" arrangement used for this particular installation. The Power Supply was located behind the Refrigerator space, so a longer "Chase"than normal was required to be cut into the floor. The dark tube also running along this chase is a piece of 10mm Flexible Conduit down which the Floor Temperature Sensor will be pushed to enable the Thermostat to monitor and hence control the floor operating temperature. The Flexi Conduit is run up through the wall to the Flush Box, along with the Cold Tails themselves. Note the position of the end of the Flexi Conduit in the floor. It is sealed (with electrical tape) and positioned to be midway between two elements as spaced on the mat.
To change direction & heat around shapes, the mat backing can be cut (but NOT the Element) and/or element can be removed from the backing mat and glued or taped to the floor as required.
  
  
A general ViewA general view
Typical Bathroom / En suiteTypical Bathroom / En suite
  
A large undertile heated area
A typical layout of a large heated area involving multiple heating elements.
  

The following examples are of typical Cold Tail installations.

An installation involving 3 elements and hence sets of Cold TailsAn installation involving 2 elements hence 2 sets of Cold Tails
Installation involving 3 elements hence 3 sets of Cold TailsInstallation involving 2 elements hence two sets of Cold Tails. You can also see clearly were a Glue Gun has been used to secure the elements and flexible conduit to the floor.
  
Singel Cold Tail exampleSingle Cold Tail with a sawcut floor chase
Single Element Cold TailSingle Element Cold Tail with Saw cut floor chase
  
Overview of a multiple element installatiion
 Multiple element installation example

 

 